PATCHFIX CONCRETE MC40

Regular price Rf20.00

Tax included.

PATCHFIX CONCRETE MC40 
FREE FLOWING, CEMENTITIOUS MICRO CONCRETE

SMART ADVANTAGES - Non shrink: Delivers positive expansion in plastic stage. - Non segregation: Highly stable segregation free grout. - Workability: Free fowing. can be pumped, trowelled or           
poured. - High early strength: Ensure rapid installation. - Iron free: No metallic iron is included in the mix as it is    
capable to introduce future deterioration due to 
rust expansion. - Other features: Can be blended with clean local aggregate 
from 6mm to 10mm for additional thickness.  - Chloride free: Good early strength development without  
the use of chlorides. 
TECHNICAL CHARACTERISTICS 
Formerly known as Elastocoat) 
Wet Density:  2200 kg/cu.m. 

DESCRIPTION 
PATCHFIX CONCRETE MC40 is a pre-packed cementitious 
micro concrete requiring only the addition of clean water to 
produce a multi-application non shrink repair concrete at the 
site. 
It is a special and unique blend of cements, graded sands, 
water reducing agents and special auxiliary chemical to deliver 
expansion in the plastic state to compensate for shrinkage. 

AREAS OF APPLICATION 
PATCHFIX CONCRETE MC40 is formulated for a wide range of 
applications such as repairing of damaged concrete structure. 
Typical areas of application are: 
• Grouting in column base, base infilling 
• Filling core holes, rod holes and defects in concrete 
• Fill in grout for hollow block walls 
• Joints between precast panels and other joints 
• Tile slab panels 
• Replacement of honeycombed or defective structural 
concrete 
Yield 
16 litres / per 30 kg bag  
(flowable consistency) 
Initial setting time 
5.5 hrs 
Final setting time 
8 hrs 
Compressive strength (N/mm2) 
1 day 
10 (N/mm2) 
7 days 
30 (N/mm2) 
28 days 
40 (N/mm2) 

APPLICATION 

PLANNING:  Plan surface preparation, formwork, fixing base 
plate, mixing, and placing equipment, manpower and quantity 
of grout required. 

SURFACE PREPARATION:  The substrate must be clean, sound 
and free from oil, grease, curing compound or any loose 
material. It must be mechanically abraded back to a sound 
concrete. Bolts or anchor holes must be clean and free from 
dust or loose material. This can be achieved by blowing clean 
the hole. 

PRE-SOAKING: It is essential to pre-soak the concrete 
substrate prior to application of PATCHFIX CONCRETE MC40 
Pre-soak substrate with water for a minimum of 6 hours prior 
to repairing. Immediately before pouring, the excess water 
should be removed. 

Formwork: It is essential that the formwork be constructed to 
facilitate rapid continuous and complete filling at area to be 
grouted. It is essential that the formwork constructed be leak 
proof and watertight. Foam rubber strips of suitable sealants 
underneath the formwork are recommended. Formwork 
should allow gravity flow of grout between the base plate and 
foundation ensuring grout is kept in full contact with base 
plate and concrete substrate.  

LOW TEMPERATURE WORKING: Normal precautions for winter 
working cementitious materials should then be applied. At 
temperatures below 5ºC the cure rate and strength 
development rate will be dramatically reduced. If early 
strength is required, it is advisable to use heated water and 
condition PATCHFIX CONCRETE MC40 to 250C. Do not exceed 
this temperature. 

HIGH TEMPERATURE WORKING: At temperatures above 30ºC, 
it is advisable to use water below 20ºC when mixing grout. All 
materials must be kept cool and away from direct sunlight with 
installation area to be shaded by erecting shade screeds. If 
ambient temperatures are excessive, perform grouting in early 
morning or late evening. 

MIXING: Water per 30 kg of PATCHFIX CONCRETE MC40 
For Flowable consistency - 5.7 – 6 lit